• Mar 26, 2024 News!Vol.16, No. 1 has been published with online version.   [Click]
  • Jan 02, 2024 News!All papers in IJET will be publihsed article by article staring from 2024.
  • Nov 03, 2023 News!News | Vol.15, No. 4 has been published with online version.   [Click]
General Information
    • ISSN: 1793-8236 (Online)
    • Abbreviated Title Int. J. Eng. Technol.
    • Frequency:  Quarterly 
    • DOI: 10.7763/IJET
    • Managing Editor: Ms. Jennifer Zeng
    • Abstracting/ Indexing: Inspec (IET), CNKI Google Scholar, EBSCO, ProQuest, Crossref, etc.
    • E-mail: ijet_Editor@126.com
Editor-in-chief
IJET 2015 Vol.7(1): 1-7 ISSN: 1793-8236
DOI: 10.7763/IJET.2015.V7.755

Flexural Characteristics of Reinforced Concrete Beam Using Styrofoam Filled Concrete (SFC) in Tension Zone

Yasser, Herman Parung, Muhammad W. Tjaronge, and Rudy Djamaluddin

Abstract—It is well known that the concrete in the tension zone is neglected in the design. Therefore, it is reasonable if the concrete on the tension zone uses a low compressive strength concrete by mixing them with the Styrofoam grains. The concrete that filled with the concrete grains is named with Styrofoam Filled Concrete (SFC). Styrofoam as waste can be used as a filler to reduce the volume of concrete, especially for areas where the concrete section is neglected in design. SFC used in this study were with 30% Styrofoam volume fractions. Results indicated that the BN had maximum flexural load of 38.8 kN, while BTL had decreased load of 24.2 kN and BTR of 36.0 kN, close to the normal beam specimen. Loading test of the BSC and BSCTR had maximum load of 38.2 kN and 48.3 kN, respectively. It can be concluded that the use of SFC in tension zone of the concrete beams showed a good agreement in performance compared to the normal reinforced concrete beams. The use of truss system reinforcement can increase the strength of the loading capacity of the beam is significant compared to the vertical reinforcement.

Index Terms—Flexural strength, monotonic loading, styrofoam filled concrete beams, truss system reinforcement.

The authors are with the Civil Engineering Department, Hasanuddin University, Makassar, Post Code 90245 Indonesia (e-mail: yasser_7727@yahoo.com, herman_parung@hotmail.com, tjaronge@yahoo.co.jp, rudy0011@hotmail.com).

[PDF]

Cite: Yasser, Herman Parung, Muhammad W. Tjaronge, and Rudy Djamaluddin, "Flexural Characteristics of Reinforced Concrete Beam Using Styrofoam Filled Concrete (SFC) in Tension Zone," International Journal of Engineering and Technology vol. 7, no. 1, pp. 358-365, 2015.

Copyright © 2008-2024. International Journal of Engineering and Technology. All rights reserved. 
E-mail: ijet_Editor@126.com