IJET 2013 Vol.5(6): 657-661 ISSN: 1793-8236
DOI: 10.7763/IJET.2013.V5.636

Strengthening of Reinforced Concrete Slab-Column Connection Subjected to Punching Shear with FRP Systems

G. I. Khaleel, I. G. Shaaban, K. M. Elsayedand, and M. H. Makhlouf

Abstract—This study aims to determine the efficiency of using Fiber Reinforced Polymers (FRP) systems to strengthen the slab–column connections subjected to punching shear. The used strengthening systems consisted of external FRP stirrups made from glass and carbon fibers. The stirrups were installed around the column. Also, external steel links were used as a conventional strengthening method for comparison. Over the last few years, the use of FRP for strengthening of concrete structures has been investigated by many researchers, whichconcerning with the strengthening of reinforced concrete slabs, beams and columns. The use of FRP in strengthening concrete slabs in flexure is done by bonding it to the tension face of the slabs. The use of FRP for strengthening the flat slabs against punching shear can be considered as a new application. This research shows the results obtained from an experimental investigation of 4 half-scale two-way slab-column interior connections, which were constructed and tested under punching shear caused by centric vertical load. The research included one unstrengthened specimen, which considered as control specimen, one specimen strengthened with steel links, one specimen strengthened with external stirrups made from Glass Fiber Reinforced Polymer (GFRP), and one specimen strengthened with external stirrups made from Carbon Fiber Reinforced Polymer (CFRP). So, the type of strengthening material is the basic parameter in this study. The experimental results showed a noticeable increase in punching shear resistance and flexural stiffness for the strengthened specimens compared to control specimen. Also, the strengthened tested slabs showed a relative ductility enhancement. Finally, equations for punching shear strength prediction of slab-column connections strengthened using different materials (Steel, GFRP & CFRP) were applied and compared with the experimental results.

Index Terms—Strengthening of Reinforced Concrete Slab-Column Connection Subjected to Punching Shear with FRP Systems

The authors are with the Civil Engineering Department, Faculty of Engineering in Benha, Benha University, Egypt (e-mail: gamal22_2@yahoo.com, igshaaban@mailer.eun.eg, khelsayed@hotmail.com; mohamedmakhlouf83@yahoo.com).

[PDF]

Cite:G. I. Khaleel, I. G. Shaaban, K. M. Elsayedand, and M. H. Makhlouf, "Strengthening of Reinforced Concrete Slab-Column Connection Subjected to Punching Shear with FRP Systems," International Journal of Engineering and Technology vol. 5, no. 6, pp. 657-661, 2013.

Copyright © 2008-2024. International Journal of Engineering and Technology. All rights reserved. 